MasterForce SM3051M Especificaciones Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 38
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
Fig.12
9. Removethearborbolt(4),thecollar(6),and
theblade(7).Donotremovetheinnerblade
collar.(Fig.13)
10.Raisethelowerclearplasticbladeguard(1)
totheuprightpositiontoremovetheblade.
(Fig.11)
NOTE:Payattentiontothepiecesremoved,noting
theirpositionanddirectiontheyface.Wipethe
bladecollarscleanofanysawdustbeforeinstalling
anewblade.Also,the12"bladehasa1"arborhole
witha5/8"reducertomountontothesaw.
Fig.13
4
INSTALLING BLADE (FIG. 11,12, 13)
CAUTION
Un=piug the miter saw before changing/
installing the blade,
1. install a 12 in. blade with a 5/8 in. arbor (or a
1 in. arbor with a 5/8 in. reducer) making sure
the rotation arrow on the blade matches the
clockwise rotation arrow on the upper guard,
and the blade teeth are pointing downward.
2. Place the collar (6) against the blade and on
the arbor. Thread the arbor bolt (4) on the
arbor in a counterclockwise direction. (Fig. 13)
IMPORTANT: Make sure the flats of the blade
collars are engaged with the flats on the arbor
shaft. Also, the flat-side of the collar must be
placed against the blade.
3. Place the blade wrench on the arbor bolt.
4. Press the arbor lock (5), holding it in firmly
while turning the blade counterclockwise. When
it engages, continue to press the arbor lock in,
while tightening the arbor bolt securely. (Fig. 12)
5. Rotate the cover plate (3) back to its original
position until the slot in the cover plate
engages with the cover plate screw (2). While
15
holding the lower blade guard, tighten the
screw with a Phillips screwdriver. (Fig. 11)
NOTE: The lower blade guard must be raised
to the upright position to access the cover
plate screw.
6. Lower the clear retractable blade guard (1)
and verify the operation of the guard does not
bind or stick (Fig. 11 ).
7. Be sure the arbor lock is released so the
blade turns freely by spinning the blade until
the arbor lock disengages.
CAUTION
® To avoid injury, never use the saw without
the cover plate secure in place, it keeps the
arbor bolt from falling out if it accidentally
loosens, and helps prevent the spinning
blade from coming off the saw,
® Make sure the collars are clean and
properly arranged. Lower the blade into
the table and check for any contact with
the metal base or the turn table,
BEVEL STOP ADJUSTMENTS
(FIG, 14, 15, 16, 17)
CAUTION
To avoid injury from unexpected starting or
electrical shock, make sure the trigger is
released and remove the power cord from the
power source,
90°(0 °) Bevel adjustment (Fig. 14)
1. Loosen bevel lock handle (2) and tilt the
cutting arm while pushing in the bevel detent
pin (1) in against the 0 ° bevel stop. Tighten the
bevel lock handle.
2. Place a combination square on the miter table
with the rule against the table and heel of the
square against the saw blade.
3. If the blade is not to the miter table, loosen
the four adjustment bolts (3) at the rear of
the unit with a 5 mm hex wrench. Unlock the
bevel lock handle (2) and adjust the cutting
arm zero degrees to the table. Tighten the
bevel lock handle and the four adjustment
bolts after alignment is achieved.
Fig. 14
\
Vista de pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 37 38

Comentarios a estos manuales

Sin comentarios